| Capacitance (µF ±20%) | 0,03-0,5 |
| Resistance (Ω ±30%) | 120 (1/4W), 120 (1/2W) |
| Dimensions W (mm) | 16-23 |
| Dimensions H (mm) | 16-28 |
| Dimensions T (mm) | 7-11,5 |
| Dimensions F (mm) | 12,5-20 |
| Dimensions D (mm) | 0,6±0.05, 0,8±0.07 |
| Dimensions L (mm) | 15-20 |
| Peak to peak | 650V max. |
| Pulse width | 20-50msec.max. |
| Repetitive frequency | 120Hz. max. |
| Pulse width (sec) x Frequency (Hz) | 0,5-3max. |
| Peak Pulse Voltage | 700V |
| Test Voltage | Line to Line 750Vdc or 375Vac 50/60Hz 60sec Line to Case 1,500Vac 50/60Hz 60sec |
| Insulation Resistance Line to Case (MΩ min.) | Line to Line 10,000MΩ min. Line to Case 100,000MΩ min. (S series: at 500Vdc SB series: at100dc) |
| Capacitance (µF ±20%) | 0,03-0,5 |
| Resistance (Ω ±30%) | 120 (1/4W), 120 (1/2W) |
| Dimensions W (mm) | 16-23 |
| Dimensions H (mm) | 16-28 |
| Dimensions T (mm) | 7-11,5 |
| Dimensions F (mm) | 12,5-20 |
| Dimensions D (mm) | 0,6±0.05, 0,8±0.07 |
| Dimensions L (mm) | 15-20 |
| Peak to peak | 650V max. |
| Pulse width | 20-50msec.max. |
| Repetitive frequency | 120Hz. max. |
| Pulse width (sec) x Frequency (Hz) | 0,5-3max. |
| Peak Pulse Voltage | 700V |
| Test Voltage | Line to Line 750Vdc or 375Vac 50/60Hz 60sec Line to Case 1,500Vac 50/60Hz 60sec |
| Insulation Resistance Line to Case (MΩ min.) | Line to Line 10,000MΩ min. Line to Case 100,000MΩ min. (S series: at 500Vdc SB series: at100dc) |
| Capacitance (μF±20%) | 0,01-0,2 |
| Resistance (Ω±30%) | 120 (1/4W), 120 (1/2W) |
| W (mm) | 16-24,5 |
| H (mm) | 13,5-17 |
| T (mm) | 6-8,5 |
| F (mm) | 14-22,5 |
| d (mm) | 0,6±0.05, 0,8±0.07 |
| Peak to peak | 800V max. |
| Pulse width | 50msec max. |
| Repetitive frequency | 120Hz max. |
| Pulse width (sec) x Frequency (Hz) | 0,15-1,5max. |
| Peak Pulse Voltage | 1,2V |
| Test Voltage | Line to Line 1,000Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec |
| Insulation Resistance | Line to Line 15,000MΩmin. Line to Case 100,000MΩmin. (at 100Vdc) |
| Capacitance (μF±20%) | 0,03-0,1 |
| Resistance (Ω) | 10-120(1/2W), 120(1/4W) |
| W (mm) | 18-20 |
| H (mm) | 12-17 |
| T (mm) | 5-8 |
| F (mm) | 16-17,5 |
| Peak to peak | 700V max. |
| Pulse width | 20-50msec max. |
| Repetitive Frequency | 120(60)Hz max. |
| Pulse width (sec) x Frequency (Hz) | 3(0.8) max., 6(1.5) max., 10(2.5) max. |
| Peak Pulse Voltage | 700-800V |
| Test Voltage | Line to Line 1,250Vac 50/60Hz 2~5sec Line to Case 2,000Vac 50/60Hz 60sec, Line to Line 2,000Vdc or 1,080Vac Line to Case 2,000Vac |
| Insulation Resistance | Line to Line 15,000MΩmin. Line to Case 100,000MΩmin. (at 100Vdc) |
| Capacitance (μF±20%) | 0,03-0,1 |
| Resistance (Ω) | 10-120(1/2W), 120(1/4W) |
| W (mm) | 18-20 |
| H (mm) | 12-17 |
| T (mm) | 5-8 |
| F (mm) | 16-17,5 |
| Peak to peak | 700V max. |
| Pulse width | 20-50msec max. |
| Repetitive Frequency | 120(60)Hz max. |
| Pulse width (sec) x Frequency (Hz) | 3(0.8) max., 6(1.5) max., 10(2.5) max. |
| Peak Pulse Voltage | 700-800V |
| Test Voltage | Line to Line 1,250Vac 50/60Hz 2~5sec Line to Case 2,000Vac 50/60Hz 60sec, Line to Line 2,000Vdc or 1,080Vac Line to Case 2,000Vac |
| Insulation Resistance | Line to Line 15,000MΩmin. Line to Case 100,000MΩmin. (at 100Vdc) |
| Capacitance μF±20% | 0,01-0,5, 1,01.00 |
| Resistance Ω±30% | 10-470(1/4W), 10-470(1/2W), 10-220(1W) |
| W | 17-47 |
| H | 14-33,5 |
| T | 7-22 |
| F | 15-43,5 |
| d | 0,6±0.05, 0,8±0.07, 10,1±0.01 |
| Peak to peak | 800V max. |
| Pulse width | 50 msec max. |
| Repetitive Frequency | 120 Hz |
| Pulse width (sec) x Frequency(Hz) | 0,02-4,5max. |
| Peak Pulse Voltage | 1,2 V |
| Test Voltage | Line to Line 1,250Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec |
| Insulation Resistance | Line to Line 15,000MΩmin. except XE0105 0475/01010 5,000Ω·Fmin. Line to Case 100,000MΩmin. (at 100Vdc) |
| Capacitance μF±20% | 0,01-1 |
| Resistance Ω±30% | 10-470(1/4W), 10-470(1/2W), 10-220(1W) |
| W | 16-37 |
| H | 18-48 |
| T | 8-22 |
| F | 12,5-33 |
| Peak to peak | 800V max. |
| Pulse width | 50msec max. |
| Repetitive frequency | 120Hz max. |
| Pulse width (sec) x Frequency (Hz) | 0,02-4,5max. |
| Peak Pulse Voltage | 1,2V |
| Test Voltage | Line to Line 1,250Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec, Line to Line 1,250Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec |
| Insulation Resistance | Line to Line 15,000MΩmin. except XEB0105 0475/01010 5,000Ω·Fmin. Line to Case 100,000MΩmin. (at 100Vdc), Line to Line 15,000MΩmin. except XEB0105 0475/01010 5,000Ω·Fmin. Line to Case 100,000MΩmin. (at 100Vdc) |
| Capacitance μF±20% | 0,1-0,5 |
| Resistance Ω±30% | 150-200(1/4W), 50-150(1/2W) |
| D | 14,5-18,5 |
| L | 38-48 |
| Peak to peak | 700V max. |
| Pulse width | 50-70msec max. |
| Repetitive frequency | 360Hz max. |
| Pulse width (sec) x Frequency (Hz) | 0,07-0,45max. |
| Peak Pulse Voltage | 800V |
| Test Voltage | Line to Line 625Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec |
| Insulation Resistance | Line to Line 10,000MΩmin Line to Case 10,000MΩmin (at 100Vdc) |
| Capacitance μF±20% | 0,1-0,5, 0,3-0,5/1 phase |
| Resistance Ω±30% | 50-200(1/2W), 50-68 (1/2W) /1 phase |
| W | 23-44 |
| H | 26-35 |
| T | 14-26 |
| F | 13-15 |
| Peak to peak | 700V max. |
| Pulse width | 50-70msec. max. |
| Repetitive frequency | 360Hz. max. |
| Pulse width (sec) x Frequency (Hz) | 0,07-0,45max. |
| Peak Pulse Voltage | 800V |
| Test Voltage | Line to Line 625Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec. |
| Insulation Resistance | Line to Line 10,000MΩmin. Line to Case CRE Series 100,000MΩmin. 3CRE Series 10,000MΩmin. (at 100Vdc) |
| Capacitance μF±20% | 0,22 |
| Resistance Ω±30% | 120 (1/2W) |
| Peak to peak | 800V max. |
| Pulse width | 50msec max. |
| Repetitive Frequency | 120Hz max. |
| Pulse width (sec) x Frequency (Hz) | 0,15 max. |
| Peak Pulse Voltage | 1,2V |
| Test Voltage | Line to Line 1,000Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec |
| Insulation Resistance | Line to Line 10,000MΩmin Line to Case 100,000MΩmin (at 100Vdc) |
| Capacitance μF±20% | 0,22 |
| Resistance Ω±30% | 120 (1/2W) |
| Peak to peak | 700V max. |
| Pulse Condition | 50msec max. |
| Repetitive Frequency | 360Hz max. |
| Pulse width (sec) x Frequency (Hz) | 0,15 max. |
| Peak Pulse Voltage | 800V |
| Test Voltage | Line to Line 625Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec |
| Insulation Resistance | Line to Line 10,000MΩmin. Line to Case 100,000MΩmin. (-FA at 100Vdc -MA at 500Vdc) |
| Capacitance μF±20% | 0,22 |
| Resistance Ω±30% | 120 (1/2W) |
| Peak to peak | 700V max. |
| Pulse Condition | 50msec max. |
| Repetitive Frequency | 360Hz max. |
| Pulse width (sec) x Frequency (Hz) | 0,15 max. |
| Peak Pulse Voltage | 800V |
| Test Voltage | Line to Line 625Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec |
| Insulation Resistance | Line to Line 10,000MΩmin. Line to Case 100,000MΩmin. (-FA at 100Vdc -MA at 500Vdc) |
| Capacitance μF±20% | 0,1-0,47, 0,33-0,47/1phase |
| Resistance Ω±30% | 33-68(6W), 27(10W), 33(6W)/1phase, 27(10W)/1phase |
| W | 30-56 |
| H | 57-62 |
| T | 15-40 |
| F | 13-28 |
| Peak to peak | 1V max. |
| Pulse width | 50-100msec.max. |
| Repetitive frequency | 720Hz max. |
| Pulse width (sec) x Frequency (Hz) | 0,2-1max. |
| Peak Pulse Voltage | 1,5V |
| Test Voltage | Line to Line 1,250Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec |
| Insulation Resistance | Line to Line 10,000MΩmin. Line to Case 100,000MΩmin. (at 100Vdc) |
| Capacitance μF±20% | 0,1-0,5, 0,3-0,5/1 phase |
| Resistance Ω±30% | 50-200(1/2W), 50-68 (1/2W) /1 phase |
| W | 23-44 |
| H | 26-35 |
| T | 14-26 |
| F | 13-15 |
| Peak to peak | 700V max. |
| Pulse width | 50-70msec. max. |
| Repetitive frequency | 360Hz. max. |
| Pulse width (sec) x Frequency (Hz) | 0,07-0,45max. |
| Peak Pulse Voltage | 800V |
| Test Voltage | Line to Line 625Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec. |
| Insulation Resistance | Line to Line 10,000MΩmin. Line to Case CRE Series 100,000MΩmin. 3CRE Series 10,000MΩmin. (at 100Vdc) |
| Product category | For 3-Phase 200V circuit |
| Specifications | Rated voltage 250VAC, Capacitance 0.33μF, Resistance value 120Ω, Operating temperature range -40 to +100℃ |
| Safety standards | UL, cUL, VDE |
| Country of origin | Japan |
| Features | For contact protection(quenching the contact spark)/ absorption of back electromotive surge voltage, Direct contact type with electromagnetic contactor(for absorbing main circuit surge), Safety atandard certified product |
| Product category | For 3-Phase 200V circuit |
| Specifications | Rated voltage 250VAC, Capacitance 0.47μF, Resistance value 47?, Operating temperature range -40 to +100℃ |
| Safety standards | UL, cUL, VDE |
| Country of origin | Japan |
| Features | For contact protection(quenching the contact spark)/ absorption of back electromotive surge voltage, Direct contact type with electromagnetic contactor(for absorbing main circui surge), Safety atandard certified product |
| Product category | For 3-Phase 200V circuit |
| Specifications | Rated voltage 250VAC, Capacitance 0.33μF, Resistance value 120Ω, Operating temperature range -40 to +100℃ |
| Safety standards | UL, cUL, VDE |
| Country of origin | Japan |
| Features | For contact protection(quenching the contact spark)/ absorption of back electromotive surge voltage, Direct connect type with electromagnet switch/ thermal relay(for absorbing main circuit surge), Safety atandard certified product |
| Product category | For 3-Phase 200V circuit |
| Specifications | Rated voltage 250VAC, Capacitance 0.33μF, Resistance value 120Ω, Operating temperature range -40 to +100℃ |
| Safety standards | UL, cUL, VDE |
| Country of origin | Japan |
| Features | For contact protection(quenching the contact spark)/ absorption of back electromotive surge voltage, Direct connect type with electromagnet switch/ thermal relay(for absorbing main circuit surge), Safety atandard certified product |
| Product category | For 3-Phase 200V circuit |
| Specifications | Rated voltage 250VAC, Capacitance 0.47μF, Resistance value 47Ω, Operating temperature range -40 to +100℃ |
| Safety standards | UL, cUL, VDE |
| Country of origin | Japan |
| Features | For contact protection(quenching the contact spark)/ absorption of back electromotive surge voltage, Direct connect type with electromagnet switch/ thermal relay(for absorbing main circuit surge), Safety atandard certified product |
| Capacitance μF±20% | 0,1-0,47, 0,33-0,47/1phase |
| Resistance Ω±30% | 33-68(6W), 27(10W), 33(6W)/1phase, 27(10W)/1phase |
| W | 30-56 |
| H | 57-62 |
| T | 15-40 |
| F | 13-28 |
| Peak to peak | 1V max. |
| Pulse width | 50-100msec.max. |
| Repetitive frequency | 720Hz max. |
| Pulse width (sec) x Frequency (Hz) | 0,2-1max. |
| Peak Pulse Voltage | 1,5V |
| Test Voltage | Line to Line 1,250Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec |
| Insulation Resistance | Line to Line 10,000MΩmin. Line to Case 100,000MΩmin. (at 100Vdc) |
| Capacitance μF±20% | 0,33 /1phase |
| Resistance Ω±30% | 120 (1/2W) /1phase |
| Peak to peak | 700V max. |
| Pulse width | 70msec max. |
| Repetitive frequency | 360Hz max. |
| Pulse width (sec) x Frequency(Hz) | 0,07 max. |
| Peak Pulse Voltage | 800V |
| Test Voltage | Line to Line 625Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec |
| Insulation Resistance | Line to Line 10,000MΩmin Line to Case 100,000MΩmin (at 100Vdc) |
| Rated Voltage | Model Number | Capacitance (μF±10%) | Width (W) | Height (H) | Thickness (T) | Lead Spacing (F) | Lead Diameter (φd) | Dissipation Factor | Test Voltage | Insulation Resistance |
|---|---|---|---|---|---|---|---|---|---|---|
| 450Vdc / 630Vdc | AFC***V474K | 0.47 | 17.0 | 14.5 | 6.5 | 15.0 | 0.6 | 0.002 max. (at 1kHz) | Rated Voltage ×1.75Vdc (2~5sec) | 7,500Ω•F min. (at 20°C,100Vdc) |
| 450Vdc / 630Vdc | AFC***V684K | 0.68 | 17.5 | 15.0 | 7.5 | 15.0 | 0.8 | 0.002 max. (at 1kHz) | Rated Voltage ×1.75Vdc (2~5sec) | 7,500Ω•F min. (at 20°C,100Vdc) |
| 450Vdc / 630Vdc | AFC***V105K | 1.0 | 17.5 | 18.0 | 9.5 | 15.0 | 0.8 | 0.002 max. (at 1kHz) | Rated Voltage ×1.75Vdc (2~5sec) | 7,500Ω•F min. (at 20°C,100Vdc) |
| 450Vdc / 630Vdc | AFC***V225K | 2.2 | 25.5 | 19.5 | 10.5 | 22.5 | 0.8 | 0.002 max. (at 1kHz) | Rated Voltage ×1.75Vdc (2~5sec) | 7,500Ω•F min. (at 20°C,100Vdc) |
| 450Vdc / 630Vdc | AFC***V335K | 3.3 | 25.5 | 22.0 | 13.5 | 22.5 | 0.8 | 0.002 max. (at 1kHz) | Rated Voltage ×1.75Vdc (2~5sec) | 7,500Ω•F min. (at 20°C,100Vdc) |
| Class | Model Number | Capacitance μF±20% | Resistance Ω±30% | Peak to peak | Pulse width | Repetitive Frequency | Pulse width (sec) x Frequency (Hz) | Peak Pulse Voltage | Test Voltage | Insulation Resistance |
|---|---|---|---|---|---|---|---|---|---|---|
| X2 | RMTE-121224 | 0.22 | 120 (1/2W) | 800V max. | 50msec max. | 120Hz max. | 0.15 max. | 1,200V | Line to Line 1,000Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec | Line to Line 10,000MΩmin Line to Case 100,000MΩmin (at 100Vdc) |
| Model Number | Capacitance μF±20% | Resistance Ω±30% | Peak to peak | Pulse Condition | Repetitive Frequency | Pulse width (sec) x Frequency (Hz) | Peak Pulse Voltage | Test Voltage | Insulation Resistance |
|---|---|---|---|---|---|---|---|---|---|
| RMTE-121224-FA | 0.22 | 120 (1/2W) | 700V max. | 50msec max. | 360Hz max. | 0.15 max. | 800V | Line to Line 625Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec | Line to Line 10,000MΩmin. Line to Case 100,000MΩmin. (-FA at 100Vdc -MA at 500Vdc) |
| RMTE-121224-MA | 0.22 | 120 (1/2W) | 700V max. | 50msec max. | 360Hz max. | 0.15 max. | 800V | Line to Line 625Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec | Line to Line 10,000MΩmin. Line to Case 100,000MΩmin. (-FA at 100Vdc -MA at 500Vdc) |
| Model Number | Capacitance μF±20% | Resistance Ω±30% | Peak to peak | Pulse Condition | Repetitive Frequency | Pulse width (sec) x Frequency (Hz) | Peak Pulse Voltage | Test Voltage | Insulation Resistance |
|---|---|---|---|---|---|---|---|---|---|
| RMTE-121224-FA | 0.22 | 120 (1/2W) | 700V max. | 50msec max. | 360Hz max. | 0.15 max. | 800V | Line to Line 625Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec | Line to Line 10,000MΩmin. Line to Case 100,000MΩmin. (-FA at 100Vdc -MA at 500Vdc) |
| RMTE-121224-MA | 0.22 | 120 (1/2W) | 700V max. | 50msec max. | 360Hz max. | 0.15 max. | 800V | Line to Line 625Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec | Line to Line 10,000MΩmin. Line to Case 100,000MΩmin. (-FA at 100Vdc -MA at 500Vdc) |
| Product category | For 3-Phase 200V circuit |
| Specifications | Rated voltage 250VAC, Capacitance 0.33μF, Resistance value 120Ω, Operating temperature range -40 to +100℃ |
| Safety standards | UL, cUL, VDE |
| Country of origin | Japan |
| Features | For contact protection(quenching the contact spark)/ absorption of back electromotive surge voltage, Direct contact type with electromagnetic contactor(for absorbing main circuit surge), Safety atandard certified product |
| Product category | For 3-Phase 200V circuit |
| Specifications | Rated voltage 250VAC, Capacitance 0.47μF, Resistance value 47?, Operating temperature range -40 to +100℃ |
| Safety standards | UL, cUL, VDE |
| Country of origin | Japan |
| Features | For contact protection(quenching the contact spark)/ absorption of back electromotive surge voltage, Direct contact type with electromagnetic contactor(for absorbing main circui surge), Safety atandard certified product |
| Product category | For 3-Phase 200V circuit |
| Specifications | Rated voltage 250VAC, Capacitance 0.33μF, Resistance value 120Ω, Operating temperature range -40 to +100℃ |
| Safety standards | UL, cUL, VDE |
| Country of origin | Japan |
| Features | For contact protection(quenching the contact spark)/ absorption of back electromotive surge voltage, Direct connect type with electromagnet switch/ thermal relay(for absorbing main circuit surge), Safety atandard certified product |
| Product category | For 3-Phase 200V circuit |
| Specifications | Rated voltage 250VAC, Capacitance 0.47μF, Resistance value 47Ω, Operating temperature range -40 to +100℃ |
| Safety standards | UL, cUL, VDE |
| Country of origin | Japan |
| Features | For contact protection(quenching the contact spark)/ absorption of back electromotive surge voltage, Direct connect type with electromagnet switch/ thermal relay(for absorbing main circuit surge), Safety atandard certified product |
| Class | Model Number | Capacitance μF±20% | Resistance Ω±30% | Peak to peak | Pulse width | Repetitive frequency | Pulse width (sec) x Frequency(Hz) | Peak Pulse Voltage | Test Voltage | Insulation Resistance |
|---|---|---|---|---|---|---|---|---|---|---|
| X2 | SK10A2E-12033 | 0.33 /1phase | 120 (1/2W) /1phase | 700V max. | 70msec max. | 360Hz max. | 0.07 max. | 800V | Line to Line 625Vac 50/60Hz 60sec Line to Case 2,000Vac 50/60Hz 60sec | Line to Line 10,000MΩmin Line to Case 100,000MΩmin (at 100Vdc) |
| Product category | For 3-Phase 200V circuit |
| Specifications | Rated voltage 250VAC, Capacitance 0.47μF, Resistance value 47Ω, Operating temperature range -40 to +100℃ |
| Safety standards | UL, cUL, VDE |
| Country of origin | Japan |
| Features | For contact protection(quenching the contact spark)/ absorption of back electromotive surge voltage, Direct connect type with electromagnet switch/ thermal relay(for absorbing main circuit surge), Safety atandard certified product |