Rotima-Logo
  • À propos de nous
  • Domaines d'application
  • Équipe
  • Emplois
  • Contact
  • Téléchargements
  • Composants électroniques
    • Nos fournisseurs
    • Produits de Bourn
      • Ceramic PTC Heaters Bourns®
      • Open LED Shunt (LSP) Bourns®
      • Switches Bourns®
      • Modular Contacts Bourns®
      • Bourns® inductors
      • Custom Magnetics Bourns®
      • Precision Sensors Bourns®
      • Commercial Panel Controls & Encoders Bourns®
      • Industrial Panel Controls Bourns®
      • Pro Audio Products Bourns®
      • Industrie Encoder Bourns®
      • Stock de produits Bourns
      • Protection des circuits
        • TBU® High-Speed Protectors Bourns®
        • Mini Breakers Bourns®
        • SinglFuse™ SMD Fuses Bourns®
        • Multifuse® Polymer PTC Resettable Fuses Bourns®
        • Multifuse® Polymer PTC freeXpansion™ Products Bourns®
        • Ceramic PTC Products Bourns®
        • Chipguard® ESD Suppressors Bourns®
        • Gas Discharge Tubes Bourns®
        • GMOV™ Hybrid Overvoltage Protection Components Bourns®
        • TCS™ High-Speed Protectors Bourns®
      • Turns-Counting Dials Bourns®
    • Filtre CEM
    • Diodes
      • Diodes Bourns®
      • Diode Arrays Bourns®
      • Power TVS Diodes Bourns®
    • Condensateurs
      • Condensateurs électrolytiques
        • Condensateurs électrolytiques à connexion vissée
        • Condensateurs électrolytiques Snap-In
        • Condensateurs électrolytiques SMT
        • Condensateurs électrolytiques radiaux
        • Condensateurs électrolytiques polymères
      • Condensateurs à film
        • Condensateurs à haute impulsion
        • Spark killer
        • Condensateurs d'antiparasitage
        • Condensateurs à film d'AIC-Europe
      • Condensateurs céramiques (MLCC)
      • Condensateurs au tantale
        • Condensateurs radiaux au tantale
        • Condensateurs tantale SMT
        • Condensateurs tantale hybrides
    • Convertisseur
      • Convertisseur de tension continue
      • Transformateur de tension
      • Transformateur de courant
    • Filtre antiparasite
      • Filtre antiparasite
      • Filtre antiparasite de réseau
    • Varistances
      • Multilayer Varistors (MLV) Bourns®
      • Metal Oxide Varistors (MOV) Bourns®
    • Thyristors
      • TISP® Thyristor Surge Protectors Bourns®
    • Potentiomètre
      • Commercial Slide Potentiometers Bourns®
      • Precision Controls Bourns®
      • Linear Motion Potentiometers Bourns®
      • Trimpot® Trimming Potentiometers Bourns®
    • Éléments piézoélectriques
    • Résistances
      • Resistor Networks Bourns®
      • Current Sense Resistors Bourns®
      • Power Resistors Bourns®
      • Résistances de mesure de courant / shunts
        • On-Board
        • Off-Board
      • Résistances à puce
      • Trimmers
      • Réseaux de diviseurs de tension
      • Résistances spécifiques au client
      • Résistances à fil
      • En fonction de la température
      • Résistances de puissance
    • Inductivités
      • Power Inductors
      • Coil Inductors
      • Chip Inductors
      • Transformateurs & Transmetteurs
    • Transistors
      • insulated-gate bipolar transistor
    • Protection des circuits
      • Dispositifs de protection contre les surtensions
      • Fusibles de température
      • Protection contre les surtensions
    • Capteurs
      • Capteurs de lumière
      • Capteurs de pression
      • Détecteurs à ultrasons
      • Capteurs d'humidité
      • Capteurs de courant
      • Potentiomètre
      • Codeur
  • Inductivités spécifiques au client
    • Transformateurs
      • Petits transformateurs
      • Autotransformateurs
      • Transformateurs d'isolement
      • Transformateurs de sécurité
      • Transformateurs toroïdaux
      • Transformateurs UI
      • Transformateurs M
      • Transformateurs EI
      • Transformateurs planaires
    • Étrangleurs
      • Réactances toroïdales
      • Inductances de stockage
    • Bobines
      • Bobines d'air
      • Corps de la bobine
      • Bobines de vernis à cuire
    • Technique d'enroulement
  • Électronique Moyens de production
    • Tissu métallique
      • Rubans de mise à la terre
      • Tresses tubulaires
      • Connecteurs de masse flexibles / bandes de mise à la terre
      • Connexions électriques
      • Solutions de CEM et de blindage
      • Solutions hautes performances et spéciales
    • Fiches / connecteurs
      • Connecteurs rapides
      • Connecteurs industriels
    • Torons
      • Torons haute fréquence
      • Fils fins
    • Ferrite
      • Noyaux en ferrite
    • Rubans d'isolation électrique
      • Bande de tissu de verre 3M - Types 27-69-79
      • Stratifié polyester 3M - Types 44-44DA-44TA-44HT-55
      • Bande tissée en acétate 3M - Types 11 - 28
      • Film époxy 3M - Types 1 - Super 10 - Super 20
      • Films polyester renforcés de fibres de verre 3M - Types 46 - 1039 - 1046 - 1076 - 1139 -1339
      • Ruban isolant électrique papier 3M - Types 12 - 16
      • Ruban isolant électrique film polyimide 3M - Types 92 - 98C-1 - 1205 - 1218
      • Ruban isolant électrique film PTFE 3M - Types 60 - 61 - 62
      • Ruban isolant électrique film PVC 3M - Scotch 22 - Super 33+ - Super 35 - Super 88
      • Ruban isolant électrique Films polyester 3M
      • Bandes de tissu électriquement conductrices
      • Feuille de blindage CEM en aluminium
      • Feuilles de blindage CEM en cuivre
    • Commutateur de température
    • Masse de scellement
    • Noyaux Impeder
    • Matériaux nanocristallins
    • Matériaux amorphes
  • Technique des tuyaux
    • Gaines thermorétractables
      • Gaine thermorétractable à froid EPDM
      • Gaine thermorétractable à paroi mince
      • Gaine thermorétractable, paroi fine, transparente Fluoropolymère RT-375
      • Découpe de la gaine thermorétractable aux dimensions spéciales souhaitées
      • Gaine thermorétractable à paroi épaisse avec adhésif intérieur
      • Gaine thermorétractable à paroi fine transparente avec adhésif intérieur
      • Gaine thermorétractable à paroi moyenne avec et sans adhésif intérieur
      • Pièces moulées thermorétractables à chaud
      • Embout thermorétractable
      • Gaine thermorétractable à paroi mince avec adhésif intérieur
      • Gaine thermorétractable à paroi mince à prix avantageux
      • Gaine thermorétractable sans halogène à paroi mince
      • Gaine thermorétractable 3:1 à paroi mince
      • Gaine thermorétractable à paroi mince jaune/vert
      • Gaine thermorétractable à paroi mince Fluoroélastomère VITON-E
      • Gaine thermorétractable super fine en PVC dur Kopalon pour packs d'accus
      • Gaine thermorétractable à paroi mince PVDF Kynar
    • Tuyaux en silicone
      • Tuyau en silicone Industrie
      • Tube en silicone Pharma
      • Tube en silicone MedTech
      • Cordon rond en silicone et monofilament
      • Tuyau en tissu de silicone - tuyau de pression
      • Gaine thermorétractable en silicone
    • Gaines de protection
      • Gaine tressée
      • Gaine thermorétractable en tissu
      • Gaine isolante en polyamide 12
      • Tuyau PA 12
    • Tuyau en plastique fluoré
      • Tuyau FEP
      • Gaine thermorétractable FEP 2:1
      • Gaine thermorétractable FEP 1,3:1 et 1,6:1
      • Gaine thermorétractable FEP 110°C
      • Revêtement de rouleau FEP avec rétraction
      • Gaine thermorétractable double paroi FEP/EFEP
      • Tuyau en PFA
      • Tuyau en PTFE
      • Gaine thermorétractable en PTFE 2:1
      • Gaine thermorétractable en PTFE 4:1
      • Gaine thermorétractable en PTFE Sub-Lite-Wall
      • Gaine thermorétractable PTFE-FEP double paroi
    • Tuyaux spéciaux
      • Tuyaux spéciaux PEEK
      • Tube en polyimide
      • Gaines thermorétractables en PEEK
    • Autres techniques de tuyaux
      • Gaines thermorétractables en PTFE
      • Tuyaux chimiques
      • Tuyaux industriels
      • Tuyaux alimentaires
    • Convertisseur AC-DC tout-en-un
    • Régulation du côté primaire Convertisseur de puissance AC-DC
    • Régulation du côté secondaire Convertisseur de puissance AC-DC
    • Convertisseur de puissance AC-DC non isolé
    • Contrôleur de redressement synchrone
Valeur ajoutée Distributeur et développement

Dispositifs de protection contre les surtensions

  • Protection fiable contre les surtensions
  • Protection contre la foudre et les surtensions
  • Installation et entretien faciles
Faire une demande directe
Demander à être rappelé
Plus de 60 ans d'expérience
dans le secteur de l'électrotechnique et de l'électronique
Délais de livraison courts
grâce à une gestion optimisée des stocks
Allemagne et Suisse
Double force du site et fiabilité

Appareils de protection contre les surtensions de Bourns

AC Surge Protective Devices
Gamme de produits de protection contre les surtensions AC
Coaxial Surge Protective Devices and Enclosures
Gamme de produits de protection contre les surtensions coaxiales
DC Power Surge Protective Devices
Applications12 V. 24 V. 48 V. 75 V. 110 V DC power supplies
Gamme de produits DC Power Surge Protective
Hybrid Protectors - MSP®
Gamme de produits Hybrid-Protectors
Line Protection Modules
Gamme de produits Line Protection Modules
Module Type
Type de module Gamme de produits
PCB Mounted Type
PCB Mounted Type Gamme de produits
Signal and Data Line Surge Protective Devices
Applications4-20 mA control loops, 4-20 mA control loops. RS-232. RS-422. RS-423. RS-485
Signal Data Line Surge-Protective
SMD Type​​​​​​​
Gamme de produits CMS

Appareils de protection contre les surtensions pour les systèmes électroniques industriels

Les appareils de protection contre les surtensions sont des composants essentiels en électrotechnique qui protègent vos appareils contre les effets dangereux de la foudre et des surtensions électriques. Ces appareils empêchent les pics de courant soudains d'endommager les équipements électroniques sensibles ou même de les rendre inutilisables. Dans notre monde moderne, dominé par la technologie, les appareils de protection contre les surtensions sont indispensables pour prolonger la durée de vie de vos appareils et éviter les pannes.
En tant que distributeur d'appareils de protection contre les surtensions, nous travaillons en étroite collaboration avec des fabricants renommés comme Okaya et Bourns.

Ces deux entreprises proposent des solutions innovantes spécialement conçues pour l'industrie électronique. Nos produits couvrent un large éventail, des solutions pour les applications basse tension aux appareils robustes pour les installations haute tension. Qu'il s'agisse de la protection de réseaux de données, de machines industrielles ou d'installations d'alimentation électrique, nos appareils de protection antisurtension vous garantissent que votre précieuse technologie reste protégée.

Grâce à notre longue expérience, nous vous proposons non seulement des produits, mais aussi des conseils sur mesure pour trouver l'appareil de protection antisurtension adapté à vos besoins spécifiques.

Appareils de protection contre les surtensions pour les appareils de mesure sensibles

Appareils de protection contre les surtensions pour les équipements de télécommunication

Demander à être rappelé
Faire une demande directe

Notre gamme de parasurtenseurs

AC Surge Protective Devices

PhotoSeriesDescriptionApplicationsData Sheet
1202 SeriesHardwired Type 1 AC Hybrid SPD - 25 kA/10 kA (Imax, In) RatedFull mode hybrid design SPD employing high energy MOV and Gas Discharge Tubes, Rated at 25 kA (8/20 µs) max./1 operation. Listed to UL 1449 4th edition. Suitable for latest NEC compliance.
1220 SeriesSurge suppressor with thermal protectionBuilt-in surge protection of electronic equipment designed to open in the event of overheating due to an abnormal overvoltage or Temporary Overvoltage (TOV) condition, interrupting any abnormal current that may be encountered, up to rated limits.
1250A SeriesDIN Rail General Duty Type 4, Type 2 AC SPD - 50 kA RatedAC protection for front end installations, main switchboard and sensitive installations without Lightning Protection Systems (LPS). SPD with advanced Thermal Disconnector (TD+).
1260 SeriesHeavy Duty Class I + Class II Hybrid AC SPD - 100 kA RatedHybrid design combining MOV and GDT technology - ideal for any AC infrastructure requiring fast responding, low leakage overvoltage protection. Rated at 100 kA (8/20 µs) and IEC/EN 61643-11 approved Class I + Class II / T1+T2.
1270 SeriesIEC Class I + Class II / T1+T2. AC SPD - 80 kA RatedRated at 12.5 kA (10/350 µs) and 80 kA (8/20 µs) with TÜV IEC/EN 61643-11 Approved Class I + Class II / T1+T2
1280 SeriesIEC Class I + Class II / T1+T2. AC SPD - 50 kA RatedRated at 7.5 kA (10/350 µs) and 50 kA (8/20 µs) with TÜV IEC/EN 61643-11 Approved Class I + Class II / T1+T2
1251 SeriesHeavy Duty Type 1 Hybrid AC SPD - 50 kA RatedHybrid design combining MOV and GDT technology - ideal for any AC infrastructure requiring fast responding, low leakage overvoltage protection. Rated at 50 kA (8/20 µs) and listed to UL 1449.
1252 SeriesHeavy Duty Type 2 Hybrid AC SPD w/Filtering - 50 kA RatedHybrid design combining MOV and GDT technology - ideal for any AC infrastructure requiring fast responding, low leakage overvoltage protection. Includes filtering for noise mitigation. Rated at 50 kA (8/20 µs) and listed to UL 1449.
1214 SeriesHeavy Duty Type 1 AC SPD - 100 kA RatedSPD Design utilizes high energy MOVs. Rated at 100 kA (8/20 µs), this series supports all common low voltage electrical distribution modes and voltages. Listed to UL 1449.
1224 SeriesHeavy Duty Type 1 AC SPD - 200 kA RatedSPD Design utilizes high energy MOVs. Rated at 200 kA (8/20 µs), this series supports all common low voltage electrical distribution modes and voltages. Listed to UL 1449.
1210 SeriesDin-Rail Heavy Duty Type 2 AC SPD - 100 kA RatedAC protection for front end installations, main switchboard and sensitive installations without Lightning Protection Systems (LPS)
1250 SeriesDin-Rail General Duty Type 2 AC SPD - 50 kA RatedAC protection for front end installations, main switchboard and sensitive installations without Lightning Protection Systems (LPS)
1200-BB Bus BarGrounding Bus BarEfficient ground connection of multiple single-pole 1210 and 1250 SPDs

Coaxial Surge Protective Devices and Enclosures

PhotoSeriesDescriptionApplicationsData Sheet
1977 SeriesHigh frequency F/N type coaxial SPD DC-4 GHzTower Mounted Amplifiers (TMA), antenna systems, GPS antennas, WiFi

DC Power Surge Protective Devices

PhotoSeriesDescriptionApplicationsData Sheet
1320 SeriesDIN Rail SPD for DC systems12 V, 24 V, 48 V, 75 V, 110 V DC power supplies
1420 SeriesDIN Rail SPD for DC systems up to 1200 VPhotovoltaic systems
1420A SeriesDIN Rail SPD for DC systems up to 1500 VPhotovoltaic systems and DC power supplies
1430 SeriesIEC Class I + Class II / T1+T2. DC SPD - 80 kA RatedRated at 12.5 kA (10/350 µs) and 80 kA (8/20 µs) with TÜV IEC/EN 61643-31 Approved Class I + Class II / T1+T2
1440 SeriesIEC Class I + Class II / T1+T2. DC SPD - 50 kA RatedRated at 7.5 kA (10/350 µs) and 50 kA (8/20 µs) with TÜV IEC/EN 61643-31 Approved Class I + Class II / T1+T2

Hybrid Protectors - MSP®

PhotoSeriesDescriptionData Sheet
155HSHeavy Duty Protection
2026-xx-XX-MSPHeavy Duty Multi-Stage 3-Electrode GDT Protector
Bourns® Digi-Guard™ MSP® ( )Maximum Protection

Line Protection Modules

PhotoSeriesApplicationsStandardsDescriptionData Sheet
4A12P-1AH-12R5Customer Premise Equipment, Central OfficeGR-1089-CORE
4A12P-506Customer Premise Equipment, Central OfficeITU-T K.20Quad resistor plus thermal fuses
4A12P-516Customer Premise Equipment, Central OfficeITU-T K.20Quad resistor plus thermal fuses
4B04B-501-XXXCustomer Premise Equipment, Central OfficeGR-1089-COREDual resistor
4B04B-502-XXXCustomer Premise Equipment, Central OfficeGR-1089-CORESingle resistor plus fuse
4B04B-523-XXXCustomer Premise Equipment, Central OfficeGR-1089-COREMatched pair of resistors
4B04B-524-XXXCustomer Premise Equipment, Central OfficeGR-1089-COREDual resistor plus fuses
4B06B-504-RCCustomer Premise Equipment, Central OfficeITU-T K.20Dual resistors plus PTCs
4B06B-512-XXXCustomer Premise Equipment, Central OfficeGR-1089-COREDual resistor plus fuses
4B06B-514-XXXCustomer Premise Equipment, Central OfficeITU-T K.20Dual resistors plus PTCs
4B06B-540-VBO1/VBO2Customer Premise Equipment, Central OfficeGR-1089-COREDual resistor plus fuses + overvoltage thyristors
4B06B-DF1-VBO1/VBO2Customer Premise Equipment, Central OfficeGR-1089-COREDual resistor plus fuses + overvoltage thyristors
4B06B-DR1-12R5Customer Premise Equipment, Central OfficeGR-1089-COREDual resistor plus fuses
4B08B-503-XXXCustomer Premise Equipment, Central OfficeITU-T K.20Dual resistor plus fuses
4B08B-513-RCCustomer Premise Equipment, Central OfficeITU-T K.20Dual resistors

Module Type

PhotoSeries nameSpecificationsSafety standardsCountory of originFeaturesData Sheet
LVRated voltage AC150/ 275/ 480/ 550V, Impulse current capacity 5000A(8/20μs), Operating temperature range -40 to 70℃UL, cUL, SEMKOJapanSPD for AC power supply, With separation function and display function, Impulse test category Class II(Type II), 1-phase type(LV-Q)/ 3-phase type(LV-U)
SVRated voltage AC150/ 275/ 480/ 550V, Impulse current capacity 5000A(8/20μs), Operating temperature range -40 to 70℃UL, cUL, SEMKOJapanSPD for AC power supply, With separation function and alarm contact function, Impulse test category Class II(Type II), 1-phase type(SV-Q)/ 3-phase type(SV-U), SCCR
LVFRated voltage AC150/ 250/ 300/ 480V, Impulse current capacity 10000A(8/20μs), Operating temperature range -40 to 70℃JapanSPD for AC power supply, "Ministry of Land, Infrastructure, Transport and Tourism" standard specification compliant, With separation function and display function, Impulse test category Class II(Type II), 1-phase type(LVF-Q)/ 3-phase type(LVF-U)
RSPDRated voltage AC125/ 250/ 420/ 500/ 600V, Impulse current capacity 5000A(8/20μs), Operating temperature range -40 to 70℃UL, cUL, TUVJapanSPD for AC power supply, Impulse test category ClassII(Type II), IEC60950 compliant, 1-phase type(RSPD-Q)/ 3-phase type(RSPD-U)
R・C・M-BQZ/ R・C・M-BUZRated voltage R・C・M-BQZ: 250/ 430V, R・C・M-BUZ: 250/ 290/ 430/ 500V, Impulse current capacity 5000A(8/20μs), Operating temperature range -40 to 70℃UL, cUL, TUVJapanSPD for AC power supply, 1-phase type(R・C・M-BQZ)/ 3-phase type(R・C・M-BUZ)
R・A・V-BWZ/ R・A・V-BXZRated voltage Delta connection: AC250V, Y connection: AC250/ 500V(R・A・V-781BWZ), AC250/ 430V(R・A・V-781BXZ), AC290/ 500V(R・A・V-801BXZ), Impulse current capacity 2500A(8/20μs), Operating temperature range -40 to +70℃UL, CSAJapanSPD for AC power supply, 1-phase type(R・A・V-BWZ)/ 3-phase type(R・A・V-BXZ)
R・A・V-BWZ-2A/ R・A・V-BXZ-2(A)/ R・A・V-BYZ-2(A)Rated voltage AC125/ 250/ 400/ 430V, Impulse current capacity 2500A(8/20μs) ※R・A・V-142BYZ-2: 1000A(8/20μs)UL, CSAJapanSPD for AC power supply, 1-phase type(R・A・V-BWZ)/3-phase type(R・A・V-BXZ/BYZ)
RGF-152-Q4/ RGF10-152-Q4Rated voltage AC250V, Impulse current capacity RGF-152-Q4: 5000A(8/20μs)/ RGF10-152-Q4: 10000A(8/20μs)UL, cULJapanSPD for LED lighting, No extarnal fuse required(Built-in separator between lines), Impulse current capacity 10,000A(8/20μs) compliant(RGF10-152-Q4)
R・A・M-BWZ(LED)/ R・A・M-BXZ(LED)/ R・A・M-BUZ-N(LED)Rated voltage AC125/ 250V, Impulse current capacity 2000A(8/20μs)TUVJapanSPD for LED lighting, Insulated wire type
R・A・M-BQZ(LED)Rated voltage AC250V, Impulse current capacity 2000A(8/20μs)JapanSPD for LED lighting, No extarnal fuse required(Built-in separator between lines)
R・A・M-LASRated voltage AC125/ 250V, Impulse current capacity 2000A(8/20μs)UL, CSA, TUVJapanSPD for AC power supply, Withstand voltage test avairable, PCB mounted type
R・A・V-LDEZ/ R・A・V-BWZ-3C/ R・A・V-BXZ-3CRated voltage AC125/ 250V, Impulse current capacity R・A・V-LDEZ: 1000A(8/20μs)/R・A・V-BWZ/BXZ: 2500A(8/20μs)UL, CSAJapanSPD for AC power supply, 1-phase type(R・A・V-LDEZ/ R・A・V-BWZ)/ 3-phase type(R・A・V-BXZ)
RSD5-485Nominal breakdown voltage 8.2V, Impulse current capacity 5000A(8/20μs)/ 2500A(10/350μs)JapanSPD for RS485/ 422 signal line, JIS C5381-21 compliant, Category C2/ D1 compliant, DIN rail connectable type
R・S・M-GLClamping voltage 30/ 60/ 70 /100V, Impulse current capacity 5000A(8/20μs)/ 2500A(10/350μs)JapanSPD for data signal line/ control line, JIS C5381-21 compliant, Category C2/ D1 compliant, PCB mounted type
R・S・M-GL-PTClamping voltage 30/ 60/ 70/ 100V, Impulse current capacity 5000A(8/20μs)/ 2500A(10/350μs)JapanSPD for data signal line/ control line, JIS C5381-21 compliant, Category C2/ D1 compliant, Terminal block type
R・S・M-GL-DINClamping voltage 30/ 60/ 70/ 100V, Impulse current capacity 5000A(8/ 20μs)/ 2500A(10/ 350μs)JapanSPD for data signal line/ control line, JIS C5381-21 compliant, Category C2/ D1 compliant, DIN rail connectable thin type
RLAN2/ RLAN3Maximum continuous operating voltage 60VAC, Impulse current capacity 5000A(8/20μs), 2500A(10/350μs)JapanSPD for LAN, Cat5e high speed LAN(1000BASE-T) compliant, IEEE802.3 at(POE) and IEEE802.3 at(POEPLUS) compliant, DIN rail connection and earth granding connectable
RLANMaximum continuous operating voltage 60VAC, Impulse current capacity 5000A(8/20μs), 1000A(10/350μs)JapanSPD for LAN, Cat5e high speed LAN(1000BASE-T) compliant, DIN rail connection and earth granding connectable
RSP-LAN-BMaximum continuous operating voltage 12.1V(L-L), Nominal breakdown voltage 15.0V±10%(L-L), Withstand impulse voltage 4000V(10/ 700μS)JapanSPD for LAN10/ 100BASE-T
RSP-TEL/ RSP-TEL-BPlease refer to the catalog.JapanSPD for telephone line, PCB mounted type/ Relay box type
RSP-485Maximum circuit voltage 6.63V(L-G), Clamping voltage 15VmaxJapanSPD for RS485/ 422 signal line, PCB mounted/ Terminal block/ DIN rail connectable type
RSP-DCDC circuit voltage 5 to 60VAC, Nominal breakdown voltage 8.2 to 82VJapanSPD for switching surge of DC power supply, SSA composite type
RLAN-IS15K-DAC withstand voltage 4000Vac-60s, Impulse Withstand Voltage Capacity 15000A-10times(1.2/50μs), Operating temperature range -25 to +75℃JapanSPD for LAN, Cat5e high speed LAN(1000BASE-T) compliant, PoE is not supported, DIN rail connection and earth granding connectable, Isolated LAN SPD that requires no grounding
GFD-300-Q4Rated voltage AC250V, Impulse current capacity 5,000A(8/20μs), Operating temperature range -40 to 90℃, Voltage protection level 1400V max.UL, cUL, UL-EUJapanProtection from induced lightning surge via AC power supply, Small size, With separation function and display function, Impulse test category Class II(Type II)

PCB Mounted Type

PhotoSeries nameSpecificationsSafety standardsCountory of originFeaturesData Sheet
RA-MX-V7-Y/ RA-MX-V7-Y(5)DC breakdown voltage 500 to 4500V, Impulse current capacity 3500A(8/20μs), Operating temperature range -20 to +80℃UL, CSA, TUVJapan, ChinaSPD for AC power supply, Glass tube type, Small size(About 3mm(height) smaller than conventional model)
RA-V7DC breakdown voltage 500 to 4500V, Impulse current capacity 3500A(8/20μs), Operating temperature range -20 to +80℃UL, CSA, TUVJapan, ChinaSPD for AC power supply, Withstand voltage test avairable(Products of DC breakdown voltage 2400V(242) or more), Glass tube type
RA-C6DC breakdown voltage 80 to 3000V, Impulse current capacity 2000A(8/20μs), Operating temperature range -20 to +80℃UL, cUL, TUVJapan, ChinaSPD for AC power supply・Protection of communication/signal/telephone line・countermeasure of the static electricity surge, Small size and quick response for surge, Withstand voltage test avairable(Products of DC breakdown voltage 2700V(272) or more), Glass tube type
R28-SDC breakdown voltage 90 to 4500V, Impulse current capacity 20000A(8/20μs), Operating temperature range -40 to +90℃JapanSPD for AC power supply or communication/ signal/ telephone line, Impulse current capacity 20kA, ITU-T compliance, Withstand voltage test avairable(Products of DC breakdown voltage 2400V(242) or more), 2-electrod tube ceramic type
R28DC breakdown voltage 90 to 6000V, Impulse current capacity 10000A(8/20μs), Operating temperature range -40 to +90℃ULJapanSPD for AC power supply or communication/ signal/ telephone line, Impulse current capacity 10kA, ITU-T compliance, Withstand voltage test avairable(Products of DC breakdown voltage 2400V(242) or more), 2-electrod tube ceramic type
R38DC breakdown voltage 90 to 600V, Impulse current capacity 10000A(8/20μs), Operating temperature range -40 to +90℃ULJapanSPD for AC power supply or communication/ signal/ telephone line, Impulse current capacity 10kA, ITU-T compliance, 3-electrod tube ceramic type
R26DC breakdown voltage 90 to 3600V, Impulse current capacity 10000A(8/20μs, 1time), Operating temperature range -40 to +90℃ULJapanSPD for AC power supply or communication/ signal/ telephone line, Impulse current capacity 5kA, ITU-T compliance, Withstand voltage test avairable(Products of DC breakdown voltage 2400V(242) or more), 2-electrod tube ceramic type
R36DC breakdown voltage 90 to 600V, Impulse current capacity 10000A(8/20μs), Operating temperature range -40 to +90℃ULJapanSPD for AC power supply or communication/ signal/ telephone line, Impulse current capacity 5kA, ITU-T compliance, 3-electrod tube ceramic type
R・A・V-L-AClamping voltage 90 to 1500V, Impulse current capacity 2400A(8/20μs)JapanSPD for communication/ signal/ telephone line・switching surge countermeasure of DC power supply・countermeasure of the static electricity surge, Varistor buit-in type
R・A・V-LDClamping voltage 220 to 620V, Impulse current capacity 2400A(8/20μs)JapanSPD for communication/ signal/ telephone line・switching surge countermeasure of DC power supply・countermeasure of the static electricity surge, Varistor buit-in type, 3 electrodes type
SSNominal breakdown voltage 8.2 to 33V, Rated peak impulse power dissipation 4200W(8/20μs)JapanSPD for communication/ signal/ telephone line・switching surge countermeasure of DC power supply・countermeasure of the static electricity surge, Array type silicon surge absorber, 4 or 8 elements/ center-common or left-common type

Signal and Data Line Surge Protective Devices

PhotoSeriesDescriptionApplicationsData Sheet
2510 SeriesDIN-Rail SPD for two data and signal line protectionRS-232 , RS-422 and RS-485 interfaces
2520 SeriesDIN-Rail SPD for two data and signal line protectionRS-232 , RS-422 and RS-485 interfaces
1500 SeriesHigh speed data line SPD for indoor/controlled environmentsGigabit Ethernet (unpowered)
1530 SeriesPower over Ethernet Surge ProtectorGigabit Ethernet (powered)
1540 SeriesPower over Ethernet (PoE) SPD for outdoor environmentsGigabit Ethernet (powered)
1669 SeriesWeatherproof/harsh environment SPD4-20 mA control loops
1675-01Railway SPD w/Visual IndicatorsProtection of Railway Signals and Track Circuits
1800 SeriesGeneral purpose DIN rail SPD for indoor/controlled environment applications4-20 mA control loops, RS-232, RS-422, RS-423, RS-485
1830 SeriesDIN rail SPD for indoor/controlled environment applicationsT1/E1 dataline
1830A SeriesT1/E1 kitT1/E1 dataline
1840 SeriesEnhanced performance design DIN rail SPD for indoor/controlled environment applicationsRS-232, RS-422, RS-423, RS-485 and with 4-20 mA and 50 mA instrumentation loops

SMD Type​​​​​​​

PhotoSeries nameSpecificationsSafety standardsCountory of originFeaturesData Sheet
RHCA5039/ RHCA5039(335)DC breakdown voltage 2400 to 3600V(RHCA53)/ 1000 to 4500V(RHCA53(335)), Impulse current capacity 2000A(8/20μs), Operating temperature range -20 to +80℃UL, cUL, UL-EUJapanSPD for AC power supply, Withstand voltage test availrable, Surface mounted ceramic type
RHCA4532DC breakdown voltage 90 to 600V, Impulse current capacity 2000A(8/20μs), Operating temperature range -20 to +80℃ULJapanSPD for communication/ signal/ telephone line, Surface mounted ceramic type
RHCA3216DC breakdown voltage 90 to 500V, Impulse current capacity 500A(8/20μs), Operating temperature range -20 to +80℃ULJapanSPD for communication/ signal/ telephone line, Surface mounted ceramic type
R5KDC breakdown voltage 75 to 600V, Impulse current capacity 5000A(8/20μs), Operating temperature range -20 to +80℃JapanSPD for communication/ signal/ telephone line, ITU-T compliance, 2-electrod tube surface mounted ceramic type
R5K3DC breakdown voltage 75 to 600V, Impulse current capacity 5000A(8/20μs), Operating temperature range -20 to +80℃JapanSPD for communication/ signal/ telephone line, ITU-T compliance, 3-electrod tube surface mounted ceramic type

Appareils de protection antisurtension pour la technique de réseau et les salles de serveurs

Les dispositifs de protection contre les surtensions dans le secteur de l'électronique sont des composants spécialisés conçus pour protéger les appareils contre les surtensions soudaines causées par la foudre ou les transitoires dans le réseau électrique. Ils se composent généralement d'éléments de protection tels que des varistances, des parafoudres à gaz ou des atténuateurs de tension transitoires qui dissipent l'excès de tension et l'empêchent ainsi d'endommager les composants électroniques sensibles. Dans les applications industrielles, les dispositifs de protection contre les surtensions sont souvent utilisés dans les commandes de machines, les réseaux de données et les systèmes de communication. Leur fonctionnement repose sur le fait qu'en cas de surtension, ils réduisent la tension à un niveau sûr, ce qui permet de prolonger la durée de vie des appareils connectés et de sécuriser leur fonctionnement.
Vous avez des questions sur notre offre d'appareils de protection antisurtension ?
Demander à être rappelé
Faire une demande directe

Notre offre d'autres composants de protection des circuits :

Sécurité de température
Sécurité de température
Protection contre les surintensités
Protection contre les surintensités
Protection contre les surtensions
Protection contre les surtensions
Vous avez des questions sur notre offre d'autres composants de protection des circuits ?
Demander à être rappelé
Faire une demande directe

Appareils de protection contre les surtensions pour les systèmes de commande électriques

Les appareils de protection contre les surtensions sont utilisés dans de nombreux domaines où les appareils électroniques sensibles doivent être protégés contre les dangers de la foudre ou des surtensions électriques. Dans l'industrie, ces appareils sont souvent utilisés pour protéger les machines de production et les systèmes de commande. Les appareils de protection antisurtension sont particulièrement indispensables dans les processus de fabrication automatisés, car ils protègent contre les pics de courant soudains qui peuvent être provoqués par la foudre ou les opérations de commutation dans le réseau électrique.

Dans le secteur de l'informatique et des télécommunications, les appareils de protection antisurtension sont également essentiels pour protéger les salles de serveurs et les technologies de réseau contre les dommages. Ici, on utilise surtout des appareils d'Okaya et de Bourns qui offrent une protection fiable contre les transitoires. En outre, on trouve des appareils de protection contre les surtensions dans les foyers modernes, où ils protègent les appareils sensibles comme les ordinateurs, les téléviseurs ou les appareils ménagers contre les surtensions. Ces solutions permettent non seulement d'éviter les pannes d'appareils, mais contribuent également à prolonger la durée de vie de votre électronique.
Électronique de puissance Appareils de protection contre les surtensions
Que pouvons-nous faire pour vous ?
Contactez nos experts produits
Tobias Nuffer
Tobias Nuffer
Directeur général & Key Accounting FR
+49 8341 93403 20
[email protected]
Faire une demande directe
Demander à être rappelé
Que pouvons-nous faire pour vous ?
Contactez nos experts produits
Rotima Andrei Jantea
Andrei Jantea
Sales- and Productmanagement
+41 44 927 26 44
[email protected]
Faire une demande directe
Demander à être rappelé

Vous avez des questions sur :

Dispositifs de protection contre les surtensions

Envoyez-nous simplement un petit message et nous répondrons volontiers à vos questions ouvertes par téléphone ou par e-mail.
Demander maintenant
Des questions ?
Écrivez-nous !

Vous souhaitez en savoir plus sur nos produits de haute qualité ?

Nous disposons d'un grand stock, de délais de livraison courts et d'une franchise douanière!

N'hésitez pas à nous contacter, nous nousferons un plaisir de vousconseiller personnellement.
Vos contacts
Demander à être rappelé

Vous souhaitez un conseil téléphonique personnalisé ?

Il suffit alors de remplir brièvement le formulaire et nous vous contacterons.
Demander à être rappelé maintenant

Quels sont les avantages de l'utilisation de convertisseurs de tension continue par rapport aux convertisseurs de tension alternative ?

Veuillez remplir le formulaire ci-dessous pour télécharger la fiche technique de ce produit.
Tous les champs marqués dune * sont obligatoires
Envoyer

Quels sont les avantages de l'utilisation de convertisseurs de tension continue par rapport aux convertisseurs de tension alternative ?

Vous pouvez maintenant cliquer sur les documents PDF et les télécharger comme d'habitude.
X

Contactez-nous

Plus d'informations sur les appareils de protection contre les surtensions

Dans cette section, vous trouverez les réponses aux questions les plus fréquentes sur les appareils de protection antisurtension et leur utilisation. Découvrez comment ces appareils fonctionnent, pourquoi ils sont indispensables à votre électronique et comment choisir le modèle le plus adapté à vos besoins spécifiques. Nos experts ont rassemblé les informations les plus importantes pour vous aider à prendre la bonne décision pour la protection de vos appareils et systèmes.
VOTRE CHEMIN VERS NOUS EN SUISSE :
Suisse
© ROTIMA AG
Industriestrasse 14 · CH-8712 Stäfa
VOTRE CHEMIN VERS NOUS EN ALLEMAGNE :
Allemagne
© Rotima GmbH
Innovapark 20 · 87600 Kaufbeuren
Modifier votre consentement
  • Sitemap
  • Mentions légales
  • Protection des données
  • GTC
ROTIMA Marketing Cellphone Kontakt
Nous nous réjouissons
en attendant votre appel !
Suisse
+41 44 927 26 26
[email protected]
Allemagne
+49 8341 9340320
[email protected]
Chaque application est
individuel
Suisse
+41 44 927 26 26
[email protected]
Allemagne
+49 8341 9340320
[email protected]
Faire une demande
Demander à être rappelé