Performance | 50–500 VA |
Function | Supply of control logic & relays |
Use | Machine control, field devices |
Specifications | Primary 120/240 V, Inrush-VAs, UL/VDE |
Performance | 10 VA–2 kVA |
Function | Galvanic isolation for device safety |
Use | MedTech, laboratories, IT protection |
Specifications | EN 61558, UL 5085, insulation test up to 6 kV |
Performance | 100 VA–10 kVA |
Function | Protection against overvoltage |
Use | Clean rooms, test benches |
Specifications | Insulation ≥4 kV, high-quality winding |
Performance | 100 VA–5 kVA |
Function | Divide voltage without insulation |
Use | Machines, railroad technology |
Specifications | Accuracy <1 %, EMC-optimized |
Performance | 500 VA–50 kVA+ |
Function | System mains supply |
Use | Industry, buildings |
Specifications | IEC 60076, thermal / hum tests |
Performance | 50 VA–5 kVA |
Function | Compact & EMC-optimized |
Use | SMPS, audio, EMC-critical areas |
Specifications | Low wastage, quiet |
Performance | 0,5–50 VA |
Function | PCB assembly with insulation |
Use | Embedded, sensors, audio |
Specifications | UL/VDE-compliant, thermal |
Performance | 5 VA–2 kVA |
Function | Protection between network & patient |
Use | OP, diagnostic devices |
Specifications | EN 60601, ≥4 kV insulation test |
Inductance/current | 10 µH–10 mH; ≤50 A |
Function | Filter HF interference |
Applications | Power supply units, drives |
Challenges | ≥60 dB EMV, UL 94 V-0 |
Inductance/current | 50 µH–5 mH; ≤500 A |
Function | DC/DC smoothing |
Applications | Energy storage, PV |
Challenges | Heat mgmt, Inrush design |
Inductance/current | 1–100 mH |
Function | Harmonic reduction |
Applications | Inverter applications |
Challenges | Temp class F/H, EN 61558, UL 5085 |
Function | Contactless current measurement |
Applications | Power monitoring, transient meas. |
Challenges | Linearity, up to 1 MHz - Appleton, Elliott, Rockwell, Schneider, Rocoil |
Function | µH–10 mH |
Inductance/current | HF filter |
Applications | HF circuits, automation |
Challenges | ≥5 kHz, compact |
Performance | 1–100 VA |
Function | HF power & insulation |
Applications | SMPS, audio, control technology, DC/DC, resonant converters |
Specifications | 20 kHz-MHz, low leakage inductance |
Performance | 1 VA–10 kVA |
Function | HF isolation/interference suppression |
Applications | Radio, EMC filter, DC/DC, resonant converters |
Specifications | UL 1446, low leakage inductance |
Performance | like HF transformers |
Function | HF isolation & matching |
Applications | Telekom, RF |
Specifications | Compact, precise insulation |
Current/Power | several 100A possible |
Function | Suppression of common mode interference |
Applications | Converters, industry, automation, IT |
Requirements | ≥60 dB, EN 61000‑6x, RoHS |
Current/Power | 0,1–50 A |
Function | Overvoltage protection |
Requirements | UL 94 V-0, high transient resistance |