| Parameter | Technical Value |
|---|---|
| Material | PEEK (polyetheretherketone) |
| Tensile Strength (ASTM D638) | 1,309 KSI |
| Fracture stress or tensile stress | 14,503 PSI |
| Glass transition temperature | 161 °C |
| Continuous operating temperature | up to +250 °C |
| Heat resistance | up to +400 °C (ASTM NEMA MW 1000) |
| Dielectric Strength | 3570 V/mil |
| Crystallinity | 40 % |
| Size (AWG) | ID before shrinkage (mm) | ID after Shrinkage (mm) | Max. wall thickness (mm) |
|---|---|---|---|
| 17 | 0.965 | 0.686 | 0.178 |
| 14 | 2.159 | 1.524 | 0.178 |
| 10 | 3.175 | 2.261 | 0.178 |
| 6 | 5.080 | 3.632 | 0.178 |
| 2 | 8.026 | 5.740 | 0.178 |
| 0 | 9.957 | 7.112 | 0.178 |
| Size (AWG) | ID before shrinkage (mm) | ID after Shrinkage (mm) | Max. wall thickness (mm) |
|---|---|---|---|
| 17 | 0.965 | 0.686 | 0.178 |
| 14 | 2.159 | 1.524 | 0.178 |
| 10 | 3.175 | 2.261 | 0.178 |
| 6 | 5.080 | 3.632 | 0.178 |
| 2 | 8.026 | 5.740 | 0.178 |
| 0 | 9.957 | 7.112 | 0.178 |
| Parameter | Specific value | Technical Classification |
|---|---|---|
| Shrinkage ratio | 1.4:1 to 2:1 | Standard Cover |
| Continuous operating temperature | +260 °C | Thermal Load Limit |
| Glass transition temperature | +143 °C | Onset of softening |
| Melting point | +334 °C | Phase transformation |
| Tensile Strength (23°C) | 92 - 100 MPa | Mechanical Strength |
| Dielectric constant | 3.2 - 3.3 | Insulation Quality at 1 kHz |
| Water absorption | < 0.1 % | Hydrolysis resistance |
| Chemical Resistance | Broadband | Resistant to oils and acids |
| Fire Behavior | UL 94 V-0 | Inherent Flame Retardancy |
| Parameter | Specific value | Technical Classification |
|---|---|---|
| Surface energy | On Sale | Nonstick properties |
| CIP/SIP Compatibility | Complete | Pharmaceutical Cleaning Processes |
| Extraction Behavior | Close to zero | Protection of the process medium |
| Sterilization cycles | > 1.000 | Long-term stability |
| Permeability rate | Minimal | Barrier against gases |
| Hydrolysis resistance | Up to +250 °C | Steam Resistance |
| FDA Compliance | Yes | Food Contact Approval |
| Parameter | Specific value | Technical Classification |
|---|---|---|
| Diagnostic capability | Real-time | Predictive Maintenance |
| Signal Transmission | Inductive / Capacitive | Contactless Data Collection |
| Temperature Measurement Range | Up to +250 °C | Monitoring Critical Points |
| Data Interface | IoT Gateway | Cloud/Edge Connectivity |
| Cycle Time Monitoring | < 100 ms | Real-time capability of the data |
| Scalability | System-wide | Networking of Multiple Sections |
| EMC Compliance | High | Protection of Internal Signals |
| Parameter | Specific value | Technical Classification |
|---|---|---|
| Wall thickness (shrunk) | > 0.5 mm | Focus: Mechanical Protection |
| Abrasion resistance | Extremely high | Protection Against Borehole Friction |
| Compressive strength | Up to 5,000 psi | Use in Deep Boreholes |
| Impact resistance | 80-100 J/m | Impact Resistance |
| Chemical Resistance | H2S, CO2, methane | Oil/Gas-Specific |
| Shore D hardness | 85 - 90 | Maximum surface hardness |
| Coefficient of Friction | 0.2 - 0.3 | Sliding Properties |
| Assembly Process | Infrared Tunnel | Energy-Intensive Shrinkage |
| Parameter | Specific value | Technical Classification |
|---|---|---|
| Shrinkage ratio | Up to 3:1 | Overcoming Obstacles |
| Degree of integration | Can be retrofitted | Upgrade Without Disassembly |
| Elongation (cold) | Optimized | Easy to Slide On |
| Radiation resistance | 10^9 rad | Nuclear & Aerospace Applications |
| Outgassing | TML < 1.0% | Vacuum Compatibility |
| Continuous operating temperature | +250 °C | Preserving the Value of the Legacy System |
| Shear strength | High | Protection against sharp edges |
| Parameter | Specific value | Technical Classification |
|---|---|---|
| Shielding Attenuation | > 60 dB | EMC Protection Effect |
| Coupling resistance | < 10 mOhm/m | Signal Integrity |
| Hybrid Design | PEEK + Conductive Layer | Multifunctionality |
| Surface resistance | < 10^4 ohms | Dissipative capacity |
| Frequency range | Up to 10 GHz | Broadband shielding |
| Weight Gain | + 15 % | vs. Standard PEEK |
| Assembly | Ground contact | Electrical connection required |
| Parameter | Specific value | Technical Classification |
|---|---|---|
| Shrinkage ratio | 1.4:1 to 2:1 | Standard Cover |
| Continuous operating temperature | +260 °C | Thermal Load Limit |
| Glass transition temperature | +143 °C | Onset of softening |
| Melting point | +334 °C | Phase transformation |
| Tensile Strength (23°C) | 92 - 100 MPa | Mechanical Strength |
| Dielectric constant | 3.2 - 3.3 | Insulation Quality at 1 kHz |
| Water absorption | < 0.1 % | Hydrolysis resistance |
| Chemical Resistance | Broadband | Resistant to oils and acids |
| Fire Behavior | UL 94 V-0 | Inherent Flame Retardancy |
| Parameter | Specifications |
|---|---|
| Material | Polyetheretherketone (PEEK) |
| Shrinkage ratio | 1.4:1 to 2:1 |
| Operating temperature | Continuous operation up to +260 °C |
| Shrinkage temperature | approx. +340 °C to +385 °C |
| Mechanical property | Extremely high impact and cut resistance |
| Fire Safety | UL94 V-0, lowest smoke toxicity |
| Approval / Standard | ABD0031 (Airbus), FAR 25.853 |
| Application | Mechanical protection of wiring harnesses, weight reduction |
| Parameter | Specifications |
|---|---|
| Material | PEEK |
| Operating temperature | -60 °C to +260 °C |
| Shrinkage temperature | +360 °C (process-safe) |
| Chemical Resistance | Resistant to all automotive fluids |
| Mechanical property | Extremely abrasion-resistant (abrasion protection) |
| Special feature | High stiffness (supportive function) |
| Approval / Standard | RoHS, REACH |
| Application | Protection of turbocharger sensors and engine compartment wiring |
| Parameter | Specifications |
|---|---|
| Material | PEEK |
| Chemical Resistance | Broad-spectrum (except for concentrated sulfuric acid) |
| Mechanical property | Resistant to pressure and creep |
| Operating temperature | up to +260 °C |
| Wear Protection | Protection against abrasive media |
| Approval / Standard | ISO 9001 |
| Application | Protective Covers for Stirring Shafts and Valves |
| Parameter | Specifications |
|---|---|
| Material | PEEK |
| Dielectric Strength | approx. 20-30 kV/mm (under high thermal load) |
| Rated Voltage | High-Voltage-Resistant |
| Radiation resistance | Excellent (gamma rays and X-rays) |
| Shrinkage temperature | +340 °C to +360 °C |
| Special feature | Dimensionally stable when exposed to heat |
| Application | Winding Head Insulation, Connector Protection |
| Parameter | Specifications |
|---|---|
| Material | PEEK (ultra-pure) |
| Outgassing | Extremely low (vacuum-compatible) |
| Purity | Metal-free, no ionic contamination |
| Chemical Resistance | Resistant to process gases and chemicals |
| Shrinkage ratio | 1,4:1 |
| Approval / Standard | Cleanroom-compatible |
| Application | Component Protection in Coating Systems |
| Parameter | Specifications |
|---|---|
| Material | PEEK |
| Hardness | Shore D 85 |
| Coefficient of Friction | Low (Optimized for Gliding) |
| Thermal conductivity | approx. 0.25 W/mK |
| Use | Protection of Rollers and Shafts |
| Special feature | Replaces heavy metal components |
| Application | Textile machinery, packaging equipment |
| Parameter | Specifications |
|---|---|
| Material | Medical-Grade PEEK (Class VI) |
| Biocompatibility | USP Class VI / ISO 10993 |
| Sterilizability | Autoclave, Gamma, ETO, Hot Air |
| Mechanical property | Very high stiffness (torque transmission) |
| Surface | Smooth, low friction |
| Approval / Standard | FDA-compliant |
| Application | Endoscope shafts, catheter reinforcement |
| Parameter | Specifications |
|---|---|
| Material | PEEK (High-Strength) |
| Operating temperature | +260 °C continuous load |
| Compressive strength | Excellent (prevents mechanical flow) |
| Chemical Resistance | Resistant to H2S, acids, and saltwater |
| Shrinkage ratio | 1,4:1 |
| Special feature | Resistant to hydrolysis at high pressures |
| Application | Encapsulation of Sensors for Deep Boreholes |
| Parameter | Specifications |
|---|---|
| Material | PEEK (ultra-pure) |
| Physiology | Physiologically inert, FDA-compliant |
| Cleaning | Fully Sterilizable (Steam/SIP) |
| Mechanical property | Non-porous, hard surface |
| Chemical Resistance | Resistant to cleaning alkalis |
| Approval / Standard | USP Class VI |
| Application | Protection of Filling Needles, Dosing Systems |
| Parameter | Specifications |
|---|---|
| Material | PEEK |
| Fatigue strength | Excellent under alternating bending loads |
| Mechanical property | High modulus of elasticity, extremely tough |
| Abrasion resistance | Outperforms almost all other polymers |
| Shrinkage temperature | approx. +350 °C |
| Special feature | Lightweight with maximum stability |
| Application | Cable Protection on Robot Axes and Gripper Systems |